American Standard 3475 Průvodce řešením problémů

Procházejte online nebo si stáhněte Průvodce řešením problémů pro Zdravotnický sortiment American Standard 3475. American Standard 3475 Troubleshooting guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 12
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
3475.500
COLONY/COLONY SOFT
3
5
4
4
Certified to comply with ANSI A112.18.1
Installation
Instructions
Bidet Faucet and Transfer Valve
with Speed Connect™ Drain
Congratulations on purchasing your American
Standard faucet with the Speed Connect drain, a
feature found only on American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
M968677 Rev. 1.1
Turn off hot and cold water
supplies before beginning.
CAUTION
1
BIDET FAUCET INSTALLATION
Replace UPPER GASKET (8) and WASHER (7) and
ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT (11).
Remove ESCUTCHEON (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
hole of BIDET.
COLD
HOT
BIDET
LEDGE
10
4
3a
3
8
9
1
5
2
6
SPRAY INSTALLATION
2
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
PUTTY
6
2
7
8
1
9
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES (3, 3a)
until snug against internal stop. If necessary, adjust LOCKNUT (1).
Place RUBBER RING (10) into ESCUTCHEON (4).
MOUNTING
SURFACE
4
10
2
1
3, 3a
5/16''
MIN.
Fig. A.
11
Adjustable Wrench
Screwdriver
Channel Locks
Required tools
Tubing Cutter
Phillips Screwdriver
Plumbers' Putty or
Caulking
7
1
Roughing-in
Dimensions
BIDET OUTLINE
IS SYMBOLIC
FINISHED
FLOOR
FINISHED
WALL
1-1/4 O.D. TAILPIECE
DOUCHE
SPRAY
2-1/8
DIA.
ADJ. 1-1/4
TO 2-1/4
3-7/8
5-1/2
1-3/8
DIA.
7/8 DIA.
1-1/4
MAX.
1-3/16
DIA.
2-1/4
DIA.
(C)
(H)
4-1/4
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
REAR VIEW WITH
WALL REMOVED
TRANSFER VALVE
(FOR FLUSHING
RIM OR SPRAY)
8 TO 12
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - Instructions

3475.500COLONY/COLONY SOFT3544Certified to comply with ANSI A112.18.1InstallationInstructionsBidet Faucet and Transfer Valvewith Speed Connect™ Drain C

Strany 2 - M968677 Rev. 1.1

M968796 Rev.1.1CHECK DRAIN CONNECTIONS1213TEST INSTALLED FITTINGWith HANDLES (1) in OFF position, turn on WATERSUPPLIES (2) and check all connections

Strany 3

M968796 Rev.1.1SpeedConnect™ DrainTroubleshooting GuideDisconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig

Strany 4 - OUTLINE OF BIDET

M968796 Rev.1.16STOPPER INSTALLATION PROCEDURELocked Mode: Look at the Plastic Loop at the bottom of the Stopper and noticethat the Loop is on one sid

Strany 5 - Speed Connect™ Drain

M968677 Rev. 1.1 2POP-UP DRAINTighten TAILPIECE (4) on DRAIN BODY beforeinstalling DRAIN BODY. Fig. B.DRAINBODY7354TIGHTEN LOCKNUT1REMOVE FLANGEThrea

Strany 6

Connect HOT water supply to inlet of left SHANK and COLDwater supply to right SHANK using sealant, appropriateconnectors, and COUPLING NUTS.Connect 1-

Strany 7 - 3475.301

INSTALL HANDLESCHECK DRAIN CONNECTIONS12111314TEST INSTALLED FITTINGWith HANDLES (1) in OFF position, turn on WATERSUPPLIES (2) and check all connecti

Strany 8

Speed Connect™ DrainTroubleshooting GuideDisconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.Look at th

Strany 9

STOPPER INSTALLATION PROCEDURELocked Mode: Look at the Plastic Loop at the bottom of the Stopper and noticethat the Loop is on one side of the Stopper

Strany 10 - To change direction of handle

M968796 Rev.1.13475.3013475.501COLONY/COLONY SOFT3544Certified to comply with ANSI A112.18.1InstallationInstructionsTurn off hot and cold watersupplie

Strany 11 - SpeedConnect™ Drain

M968796 Rev.1.1POP-UP DRAINTighten TAILPIECE (4) on DRAIN BODY beforeinstalling DRAIN BODY. Fig. B.DRAINBODY7342REMOVE FLANGEThread FLANGE (1) counter

Strany 12

M968796 Rev.1.1Connect HOT water supply to inlet of left SHANK and COLDwater supply to right SHANK using sealant, appropriateconnectors, and COUPLING

Komentáře k této Příručce